ERROR CODES
___________________________________________________________________
Error No. Message / Action
10-4
035 Internal Error. Call Factory.
1) Notify Link Systems of this error.
036 Failure of Automatic Setup.
This error results when the sixteen stroke automatic
setup procedure is completed properly but a hardware
failure prevents the new setpoints from being
transferred into the non-volatile memory.
1) Press the CLEAR key to clear the error.
037 Auto Setup time-out.
From the time automatic setup is begun, the operator
has one minute to make the first press stroke in the
sixteen stroke sequence. The operator also has only
one minute allowed between each successive stroke in
the sequence. If the operator fails to make a
stroke during this minute, the automatic setup
procedure is stopped, and this error results.
1) Press the CLEAR key to clear the error.
040 End of Cycle cam failure.
This error indicates that the zeroing cam switch
(when the cam zero option is used) connected to the
EOC input terminal is faulty, or that the wire from
the cam switch has come loose, been disconnected, or
is shorted to ground.
1) Check the wiring from the cam switch to the EOC
input terminal, making sure that all connections
are in tact and no short circuits exist.
2) Check the cam switch. A faulty contact is
indicated if all wiring is correct.