System 2500 Operating & Installation Manual - Revision 07 1-3
Figure 1
System 2500 Components
1.3 Specifications
Input Ratings
Primary Input Power Requirements: 115VAC ± 15VAC, 60Hz, 1 Ampere
Run Signal Input (Terminals 34 & 35): 115VAC @ 10mA nominal
or 24VDC @ 2mA nominal
Die Protection Inputs and Auto SS Input: Inputs are active low (ground); to activate,
external circuit must sink 0.6mA (typical),
1.2mA (maximum)
Output Ratings
28VAC Output: 450mA maximum
+12VDC Output (for sensors): 100mA maximum